Hycrete Products
Hycrete System V
Vapor Protection for Flooring on Concrete Slabs
Hycrete System V protects flooring against moisture in below-, on-, and above-grade concrete slabs. Hycrete System V consists of:
1. Hycrete W1000 admixture
- Reduce moisture vapor transmission through concrete
- Prevent moisture entering concrete through wicking/capillary action
- Avoid delays from rewetting
2. Hycrete-approved vapor barrier system (for below- and on-grade slabs)
3. Technical field service – ensure that all appropriate steps are taken to deliver a structure protected from vapor transmission problems
4. Hycrete IntegraTek Vapor Warranty – 10-year performance warranty
Benefits:
- Install flooring 28 days after concrete placement, even when slabs are exposed to rewetting/li>
- Reduce delays and install flooring sooner
Superior protection against moisture damage to flooring
- Avoid unsightly floors – expansion, cupping, peaking, curling, buckling, bubbling, blistering, gapping / seam separation, debonding, delamination, adhesive failure, oozing/bleeding, warping, staining, efflorescence, discoloration, mold growth, mildew, fungi
- Reduce moisture transmission through concrete and prevent water from entering concrete
Reduced construction time and related cost savings
- No delays from concrete rewetting – no need to wait for concrete to dry out sufficiently to meet moisture testing requirements
- No need to apply separate primer and wait for it to dry
- Avoid delays and call-backs related to flooring damage
Reduce risk of floor failure
- Owners and specifiers – avoid legal claims and costs related to trip hazards
- Specifiers – avoid the time and inconvenience of flooring issues from moisture damage
Reduce risk of adhesive bond failure
- Avoid alkaline conditions that can cause adhesive bonds to be destroyed
- Reduce replacement and maintenance
- Extend the life of flooring and reduce replacement frequency
Sustainable solution
- Reduce replacement requirements
- Contribute to LEED points
- No VOCs
It is estimated that over $1 billion dollars a year are spent by owners on remediating flooring due to moisture penetration. Huge areas of flooring may have to be replaced, causing disruption to a building site or to an occupied building. With Hycrete System V, you can protect against this.
Contact us to find out about using Hycrete System V for your project, or to answer any questions.


- Product Data Sheet
- MSDS
- Specifications
- Testing Summary
- Hycrete Details
- Performance Warranty
Applications for Hycrete System V include:
All flooring applications on concrete:
- Hospitals
- Schools and higher ed
- Office and administration buildings
- Institutional buildings
- Retail